dc.descriptionThesis (MEng (Energy))--Cape Peninsula University of Technology, 2020en_US
dc.description.abstractThis study aimed to explore the cost-effective mechanisms to reduce energy demand consumption in SASOL Fuels Application Centre (SFAC) building in South Africa. It focuses on the commercial facility’s total real power (kW) and reactive power (KVAR), which together contributes to high demand (KVA) spark resulting in high demand energy costs, which has a direct influence on the high electricity bills issued to commercial businesses worldwide. The demand sparks are caused by current’s instantaneous hike which as a result caused pressure to power producer. Then, the producer issues penalties in the form of demand charges resulting in a high electricity bill. The energy consumption reduction of commercial buildings can be achieved through the implementation of a power metering system to measure the total kW, KVA, KVAR and power factor. The study presents DSM techniques as a model suitable for reduction of demand load consumptions and demonstrates a range of energy conservation options available for baseline reduction to contribute to lower total electricity consumption of SFAC. The preferred method for the study was power factor improvement aimed at correcting the current spark by discharging the set of required capacitor banks to compensate for the demand. The power simulator software model was developed to simulate the real power together with the desired power factor and the reduction of approximately 10% on electricity bill was realised.en_US
dc.language.isoenen_US
dc.publisherCape Peninsula University of Technologyen_US
dc.subjectEnergy conservationen_US
dc.subjectElectric utilities -- Economic aspectsen_US
dc.subjectElectric industries -- Economic aspectsen_US
dc.subjectEnergy consumptionen_US
dc.subjectAir conditioning -- Energy consumptionen_US
dc.subjectAir conditioning -- Energy conservationen_US
dc.titleIntervention mechanisms to reduce energy consumption of air-conditioning and illumination systems for commercial buildingsen_US
dc.typeThesisen_US
Appears in Collections:Electrical, Electronic and Computer Engineering - Master's Degree
Files in This Item:
File Description SizeFormat 
Lephuthing_Fusi__215013875.pdf2.1 MBAdobe PDFView/Open
Show simple item record

Page view(s)

245
Last Week
1
Last month
9
checked on Nov 24, 2024

Download(s)

135
checked on Nov 24, 2024

Google ScholarTM

Check


Items in Digital Knowledge are protected by copyright, with all rights reserved, unless otherwise indicated.