  5. The IEC 61850 standard-based protection scheme for power transformers
 
Loading...
Thumbnail Image

The IEC 61850 standard-based protection scheme for power transformers

Author(s)
Baningobera, Bwandakassy Elenga
Date Issued
2018
Type
Thesis
Publisher
Cape Peninsula University of Technology
Abstract
Transformer Differential and overcurrent schemes are traditionally used as main and backup protection respectively. The differential protection relay (SEL487E) has dedicated harmonic restraint function which blocks the relay during the transformer magnetizing inrush conditions. However, the backup overcurrent relay (SEL751A) applied to the transformer protection does not have a harmonic restraint element and trips the overcurrent relay during the inrush conditions. Therefore, to prevent the malfunction caused by the transformer magnetizing inrush current, a novel harmonic blocking method is developed, implemented and tested in the RSCAD simulation environment. The IEEE 14 bus transmission system is considered as a case study. The IEEE 14 bus system is modelled and simulated in the DIgSILENT and RSCAD simulation environments respectively. The developed harmonic blocking scheme is implemented in the Hardware-In-the-Loop (HIL) simulation environment using Real-Time Digital Simulator and numerical protection IEDs. The developed scheme uses the Harmonic Blocking element (87HB) of the transformer differential relay (SEL487E) to send an IEC61850 GOOSE-based harmonic blocking signal to the backup overcurrent relay (SEL751A) to inhibit it from tripping during the transformer magnetizing inrush current conditions. The hardwired and GOOSE simulation results are analysed for the transformer differential protection and the backup overcurrent protection schemes for internal, external events and transformer magnetizing inrush current conditions. The simulation results proved that the IEC61850 standard-based protection scheme is faster than the hardwired. Therefore, the speed and reliability are improved using the IEC61850 standard-based GOOSE applications to the transformer digital protective relaying system.
Additional information
Thesis (MEng (Electrical Engineering))--Cape Peninsula University of Technology, 2018.
Subjects

IEC 61850 standard

Electric power transm...

Electric power system...

Electric apparatus an...

File(s)
Loading...
Thumbnail Image
Name

211055867-Elenga Baningobera-Bwandakassy-MEng-Electrical-Engineering-Eng-2018.pdf

Description
Thesis
Size

6.75 MB

Format

Adobe PDF

Checksum

(MD5):41c7121a22ade9c98a9ccbca865b5fad

  • Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify