The release of damaged prosthesis from it's cemented position in human bone

Author(s)
Kadoura, Ahmed Mohamed
Date Issued
2019
Type
Thesis
Publisher
Cape Peninsula University of Technology
Abstract
Original surgery to replace a joint in the body with an implant is known as arthroplasty. There are cases where it is necessary to replace the implant with a revision surgery, because it has worn out or infection may have developed. Revision surgery is a long and complex procedure because the orthopaedic surgeon has to remove the implant that had been cemented in the bone cavity as well as the bone cement. A major problem is the hardness of the bone cement. Several methods are used in order to remove it, requiring excessive strength and sharp tools, that pose a danger to the human body long surgery time, from 3 - 4 hours. In this study, modern methods were used attempting to soften bone cement by heating it using heating equipment (a hair dryer and a heat gun), by bombarding it with ultrasonic waves and finally applying mechanical vibrations. The heating of the bone cement did not give satisfying results, as the temperature needed for melting or softening the bone cement was very high, which is not tolerable in operations, especially dealing with the human body. The use of ultrasonic waves in trying to separate the implant from the bone cement did not give any positive results either. The exposure of bone cement to ultrasonic waves in a wide range of frequencies and for a long period of time resulted in some heating effect but did not produce any change in its mechanical or chemical properties. Mechanical vibration produced a significant difference in results with the similar samples used in the first phase (heating) and the second phase of testing (the use of ultrasonic waves). After choosing an effective vibration source (a hammer drill), an adaptor was developed for securing the "implant test" samples and ensuring that the source of vibration would apply an axial tension on the implant as it were cemented in the bone cavity. The results were very positive, in that firstly and foremost the implant was separated from the bone cavity together with the body of the cement, i.e. leaving no remnants or leftovers in the inner surface of the bone where it was cemented. The frequency of vibration for best results was found to be 40 Hz and the time period of vibration for the complete extraction of the "implant" with the cement attached to it, did not exceed 22 seconds.
Additional information
Thesis (MTech (Mechanical Engineering))--Cape Peninsula University of Technology, 2019
Subjects

Arthroplasty

Bone cements

Mechanical vibration

Biomedical engineerin...

Biomedical materials

File(s)
Loading...
Thumbnail Image
Name

Kadoura_Ahmed_215213517.pdf

Size

1.56 MB

Format

Adobe PDF

Checksum

(MD5):d9896e937aec09aa4df30b9c3df3edf5

  • Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify