Repository logo
  • English
  • Deutsch
  • Español
  • Français
Log In
New user? Click here to register.Have you forgotten your password?
  1. Home
  2. ETD - Faculty of Engineering and Built Environment
  3. Faculty of Engineering - Department of Electrical, Electronic and Computer Engineering
  4. Electrical, Electronic and Computer Engineering - Master's Degree
  5. Investigation of the communication protocol for the power plant controller
 
Loading...
Thumbnail Image

Investigation of the communication protocol for the power plant controller

Author(s)
Johnson, Rayner
Date Issued
2024
Type
Thesis
Publisher
Cape Peninsula University of Technology
DOI
https://doi.org/10.25381/cput.28706240.v1
Abstract
This research investigates the communication of photovoltaic (PV) inverters to Power Plant Controllers (PPC). Currently, the only communication option is to use the Modbus protocol, as all inverter manufacturers provide Modbus-compatible communication modules to the PV inverters. With the worldwide adoption of the International Electrotechnical Committee (IEC) 61850 standard, the MMS protocol is compared to the Modbus protocol. This investigation involves a simulation of PV systems compiled on a real-time digital simulator (RTDS) NovaCor machine. This simulation can interact with external Intelligent Electronic Devices (IEDs) through a communication card called GTNETx2. The PPC is configured using the SEL 3555 RTAC as the device and interacts with the simulation. The first iteration of the investigation is compiled using Modbus, and the second iteration modifies the communication integration with the IEC 61850 MMS protocol. Data is captured and transmitted between the RTDS NovaCor GTNETx2 card (simulation) and the SEL 3555 RTAC (PPC). This data provides insights analysed using packet analyzer software called Wireshark and IED Explorer. Interpreting the data is based on comparing the two protocols and identifying the efficiencies and functionalities of each protocol. The IEC 61850 MMS protocol displays advanced functionality such as timestamping, quality data bits, reporting, and complex adoption towards the power systems use case. However, larger packet files and more complicated configuration causes distinct disadvantages. The investigation extends to the implementation of data monitoring to develop the interpretations used for comparison.
Additional information
Thesis (MEng (Electrical Engineering in Smart Grid))--Cape Peninsula University of Technology, 2024
Subjects

Advanced communicatio...

Power Plant Controlle...

IEC 61850

Modbus

File(s)
Loading...
Thumbnail Image
Name

Johnson, RJ_ 214240525.pdf

Size

8.22 MB

Format

Adobe PDF

Checksum

(MD5):07a9c351b744a453a9f9da0ef2034d81

  • Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify