  5. Investigation of 3 terminal differential protection using standard-based numerical relays
 
Loading...
Thumbnail Image

Investigation of 3 terminal differential protection using standard-based numerical relays

Author(s)
Lwana, Mkuseli
Date Issued
2017
Type
Thesis
Publisher
Cape Peninsula University of Technology
Abstract
Transmission lines are a vital part of the electrical distribution system, as they provide the path to transfer power between generation and load. Factors like de-regulated market environment, economics, etc. have pushed utilities to operate transmission lines close to their operating limits. Any fault, if not detected and isolated quickly will cascade into a system wide disturbance causing widespread outages for a tightly interconnected system operating close to its limits. Current differential criterion is used with success to protect various elements in power systems, i.e. transmission lines, power transformers, generators and busbars. The alpha plane differential relaying system provides sensitive protection for transmission lines, security and dependability for external faults.
This thesis focuses on three terminal alpha plane differential protection with the aim to develop a complete test method using OMICRON test universe software essentially defining security, dependability and sensitivity of the alpha plane characteristic. The research analyses the three terminal alpha plane characteristic and existing primitive test methods and develops an improved test method using IEC 61850 standard. The primitive methods are time consuming and result in unnecessary prolonged outages.
These methods have been discussed and improved in the thesis by implementing IEC 61850 standard. First the standard IED Capability Description (ICD) file is modified by developing new logical nodes using AcSELerator Architect and XML Maker software. Then the developed logical nodes, three terminal differential protection alpha plane characteristic with its additional infeed/outfeed check logic, and the developed test method are tested simultaneously using Test Universe software.
A laboratory test bench is built using three SEL311L relays, two CMC 356 Omicron injection devices, PC, MOXA switch, CMIRIG-B time synchronising unit, SEL 2407 satellite synchronised clock, and a DC power supplier.
The test method developed in this research vindicates benefits of IEC 61850 standard over hard wired systems. Prolonged outage times due to test set preparation using hard wires are drastically reduced.
The thesis findings and deliverables will be used as a solution to industrial problems, postgraduate studies of other students and research project.
Additional information
Thesis (MTech (Electrical Engineering))--Cape Peninsula University of Technology, 2017.
Subjects

Electric cables

Electric power transm...

Electric lines -- Pro...

Electric power transm...

IEC61850

Ethernet

File(s)
Loading...
Thumbnail Image
Name

202055388-Lwana-Mkuseli-M.Eng-Electrical-Engineering-Eng-2017.pdf

Description
Theses
Size

4.26 MB

Format

Adobe PDF

Checksum

(MD5):084cc99dc4de85586461a15bf5f83929

  • Metrics
Get Involved!
  • Source Code
  • Documentation
  • Slack Channel
Make it your own

DSpace-CRIS can be extensively configured to meet your needs. Decide which information need to be collected and available with fine-grained security. Start updating the theme to match your Institution's web identity.

Need professional help?

The original creators of DSpace-CRIS at 4Science can take your project to the next level, get in touch!

Built with DSpace-CRIS software - Extension maintained and optimized by 4Science

  • Privacy policy
  • End User Agreement
  • Send Feedback
Repository logo COAR Notify