Abstract: This research study aimed to evaluate the performance of a standing wave thermoacoustic refrigerator and optimise the stack length and position for a single stack material. Thermoacoustic refrigerator (TAR) generally has a low coefficient of performance (COP). This has negatively impacted its development. There has been research to improve its COP, which has mostly focused on optimising the system. Numerical and experimental have been used to optimise various components of TAR. This research study combined the experimental work and numerical modelling of the standing wave TAR. Thirty experiments were conducted over three months. The experiments were done for three stack positions of 30 mm, 40 mm, and 50 mm. At each stack position, stacks of lengths of 25 mm, 35 mm, 45 mm, 55 mm, and 65 mm. In addition, numerical modelling of TAR performance was done for the three positions, with the five stack lengths for each position. The numerical modelling was done using the commercial Multiphysics software. The experiments and numerical modelling were followed by optimisation. The optimisation of the experimental data identified the optimal stack configuration as a stack position of 55 mm and a stack length of 25 mm, achieving a COP of 0.33. The optimal configuration yielded ΔT=8°C, COP=0.33, TC=25.1°C and QC=0.0532 W. On the other hand, the optimisation of numerical modelling data identified the optimal stack configuration as a stack position of 30 mm and a stack length of 25 mm, achieving a COP of 1.27. The optimal configuration yielded ΔT=8.5 K and COP=0.33. The experimental work and numerical modelling agreed regarding stack length. They both indicated an optimal stack length of 25 mm, suggesting that short stack lengths are good for a high COP while maintaining other performance metrics within acceptable ranges. The experimental work and numerical modelling differed in the optimal stack position. As a result, this study could not uncover the influence of stack position as far as optimising for a high COP is concerned.
Description: Thesis (MEng (Chemical Engineering))--Cape Peninsula University of Technology, 2024
URI: https://etd.cput.ac.za/handle/20.500.11838/4186
Appears in Collections:Chemical Engineering - Masters Degrees

Files in This Item:
File Description SizeFormat 
Kaja Tshowa, P_209159332.pdf2.43 MBAdobe PDFView/Open
Show full item record

Page view(s)

7
checked on Jan 30, 2025

Download(s)

1
checked on Jan 30, 2025

Google ScholarTM

Check


Items in Digital Knowledge are protected by copyright, with all rights reserved, unless otherwise indicated.